Data Logger

Taharica
Type T 6 ft Beaded

Range:-200 to 180°C (-330° to 356°F)-65 to 130°C (-85° to 270°F)130 to 180°C (270° to

Temperature (6 inch)

Measurement range: -40° to 100°C (-40° to 212°F)Accuracy:w/U12: ±0.25°C from 0° to 50°C

HOBO Four-Channel Data

HOBO data loggers require HOBOware software (USB interface cable included w/CD purchase) and a communications device. See compatible items below. Buffer memory: 3k

HOBO Four Analog Port

Buffer memory: 3k measurementsSample rate: 1 min to 18 hrsTransmission rate: 2 min and greaterPower options: AC power adapter, battery

HOBO Temperature Data

Buffer memory: approx. 5k measurementsSample rate: 1 min to 18 hrsTransmission rate: 2 min and greaterPower options: AC power adapter, battery

HOBO Four External

HOBO data loggers require HOBOware software (USB interface cable included w/CD purchase) and a communications device. See compatible items below. Buffer memory: approx.

HOBO Temperature Data

Temperature Sensor Range -30° to 70°C (-22° to 158°F) Accuracy ±1.0°C from -30° to

HOBO MX2304 External

Temperature Sensor Range MX2301 and MX2305 internal sensors: -40 to 70°C (-40 to 158°F)MX2302 external temperature sensor: -40 to

HOBO MX2305 Temperature

The HOBO MX2300 data loggers requires the HOBOmobile App and a compatible mobile device. The system requirements for the HOBOmobile app can be found at the bottom of our

HOBO Pendant® MX

The HOBO MX2202 data logger requires the HOBOmobile App and a compatible mobile device. The system requirements for the HOBOmobile app can be found at the bottom of our HOBOmobile

HOBO Type J, K, T, E, R,

HOBO data loggers require HOBOware software (USB interface cable included w/CD purchase) and a communications

HOBO TidbiT MX

Temperature Sensor (MX2203 and MX2204) Range MX2203: -20° to 70°C (-4° to 158°F) in air; -20° to 50°C

HOBO TidbiT MX

Temperature Sensor (MX2203) Range MX2203: -20° to 70°C (-4° to 158°F) in air; -20° to 50°C (-4° to

HOBO State Data Logger -

Internal Sensor Maximum state, event, runtime frequency: 1 HzPreferred switch state: No magnet present (normally open)   External Input External contact input:

HOBO Extended Memory

Internal Sensor Maximum state, event, runtime frequency: 1 HzPreferred switch state: No magnet present (normally open)  External Input External contact input:

Solar Radiation (Silicon

Measurement range: 0 to 1280 W/m2Operating temperature range: -40° to 75°C (-40° to

EC5 Soil Moisture Smart

Measurement RangeIn soil: 0 to 0.550(m³/m³)Extended range: -0.401 to 2.574 m³/m³ (full scale) The sensor is capable of

10HS Soil Moisture Smart

Volume of influence: 1 liter (33.8 oz)Sensor frequency: 70 MHzBits per sample: 12Number of data channels: 1Measurement averaging

HOBO 4-Channel Pulse

*HOBO data loggers require HOBOware software (USB interface cable included w/CD purchase) and a communications device. Inputs External Contact Input: Electronic solid

HOBO 4-Channel Pulse

Inputs External Contact Input: Electronic solid state switch closure or logic driven digital signals to 24 V Maximum Pulse Frequency: 120 Hz Maximum State,

Replacement RH Sensor

Compatible Items: USB Data Loggers - internal sensors only U14-001LCD - Temperature/Relative Humidity (RH) Data

Replacement RH Sensor

Compatible items:  USB Data Loggers -internal sensors only U14-001LCD - Temperature/Relative Humidity (RH) Data Logger  UX100-011Temp/RH 2.5% Data

HOBO Rain Gauge (Metric)

Rain GaugeMaximum rainfall rate: 12.7 cm (5 in.) per hourCalibration accuracy: ±1.0% (up to 1 in./hour for the RG3 or 20 mm/hour for the

HOBO Rain Gauge Data

Rain GaugeMaximum rainfall rate: 12.7 cm (5 in.) per hourCalibration accuracy: ±1.0% (up to 1 in./hour for the RG3 or 20 mm/hour for the

0.2 mm Rainfall (2m

Measurement range: 0–12.7 cm or 0–5 in. per hour; maximum 4000 tips per intervalOperating range: 0° to 50°C (32° to

0.01" Rain Gauge

Measurement range: 0–10 cm or 0–5 in. per hour; maximum 4000 tips per intervalOperating range: 0° to 50°C (32° to

Davis® 0.01"

Measurement Range 0 to 10.2 cm (0 to 4 in.) per hour, maximum 4,000 tips per logging interval Accuracy ±4.0%, ±1 rainfall count

Davis® 0.2 mm Rain

  Measurement Range 0 to 10.2 cm (0 to 4 in.) per hour, maximum 4,000 tips per logging interval Accuracy ±4.0%, ±1

Contact Closure Pulse

Maximum input frequency: 2 Hz (2 pulses per second)Measurement range: 0 – 65,533 pulses per logging intervalResolution: 1 pulseLockout

Electronic Switch Pulse

Maximum input frequency: 120 Hz (120 pulses per second)Measurement range: 0 – 65,533 pulses per logging intervalResolution: 1 pulseLockout

Contact Closure Pulse

Maximum input frequency: 2 Hz (2 pulses per second)Measurement range: 0 – 65,533 pulses per logging intervalResolution: 1 pulseLockout

Electronic Switch Pulse

Maximum input frequency: 120 Hz (120 pulses per second)Measurement range: 0 – 65,533 pulses per logging intervalResolution: 1 pulseLockout

HOBO Bluetooth Low

pH Sensor   pH mV Range 2.00 to 12.00 pH -512 to 512 mV Accuracy ±0.10 pH units within ±10°C of temperature at

Photosynthetic Light

Measurement parameters: average over logging interval, user-defined sampling interval from 1 secondMeasurement range: 0 to 2500 umol/m2/sec, wavelengths of 400

HOBO Occupancy/Light (5m

Occupancy Sensor Detection range: UX90-005x: maximum 5 m (16.4 ft)Detection PerformanceUX90-005x: 94° (±47°) Horizontal;

HOBO Occupancy/Light

Occupancy Sensor Detection RangeUX90-005x: maximum 5 m (15.4 ft);UX90-006x: maximum 12 m (39.4 ft)Detection PerformanceUX90-005x: 94°

HOBO Extended Memory

Occupancy Sensor Detection RangeUX90-005x: maximum 5 m (16.4 ft);UX90-006x: maximum 12 m (39.4 ft)Detection PerformanceUX90-005x: 94°

HOBO Extended Memory

Occupancy Sensor Detection RangeUX90-005x: maximum 5 m (15.4 ft);UX90-006x: maximum 12 m (39.4 ft)Detection PerformanceUX90-005x: 94°

HOBO Extended Memory

Internal Motor Sensor AC magnetic field threshold: > 40 mGauss at 60 Hz    External Input External contact input: Electronic solid state switch

HOBO Motor On/Off Data

Internal Motor Sensor AC magnetic field threshold: > 40 mGauss at 60 Hz  External Input External contact input: Electronic solid state switch closure or

Occupancy/Light (12m

Produk ini berasal dari Amerika Serikat. Untuk melihat spesifikasi lengkap produk ini, jika tersedia lihat manual book yang terdapat pada tab dokumentasi.   Occupancy

Light On/Off Data Logger

Spesification Produk ini berasal dari Amerika Serikat. Untuk melihat spesifikasi lengkap produk ini, jika tersedia lihat manual book yang terdapat pada tab

Leaf Wetness Smart

Produk ini berasal dari Amerika Serikat. Untuk melihat spesifikasi lengkap produk ini, jika tersedia lihat manual book yang terdapat pada tab dokumentasi.   Measurement

EG4130 Pro - 30 Input

Pengukuran Tegangan AC: L1: 85-277 Vrms L2: 0-277 Vrms L3: 0-277 Vrms Tegangan DC: 42 Vrms Daya: 9-60 Vdc Pengukuran: +/- 60 Vdc Saat ini: 30 saluran 5-6900A maks per

Veris Kilowatt Hour

Frequency: 50 to 60Hz Accuracy: ±1% (3-phase model conforms to ANSI C12.1 metering standards) CT range: 0-300 Amp (T-VER-8051-300); 0-800 Amp

WattNode 480 VAC 3-phase

Operating: voltage range: ±20% of nominal Frequency: 60 Hz CT input: 0-0.5 VAC operating, 3 VAC maximum Connectors: UL, CSA recognized, detachable screw terminals

WattNode 208-240VAC 2 or

Wye configuration ranges: 120, 208, 240 Volts AC - Neutral required    1 Phase 2 Wire 120V (with neutral)    1 Phase 3 Wire

kWh Monitoring Kit

Flexibility to log up to 500,000 single or three phase measurements running 240 to 480 volts LCD display to enable easy viewing of latest kWh readings Priced significantly

Veris Kilowatt Hour

Frekuensi: 50 hingga 60Hz Akurasi: ± 1% (model 3-fase sesuai dengan standar pengukuran ANSI C12.1) Rentang CT: 0-300 Amp (T-VER-8051-300); 0-800 Amp

WattNode 208/240 VAC

Operating: voltage range: ±20% of nominal Frequency: 60 Hz CT input: 0-0.5 VAC operating, 3 VAC maximum Connectors: UL, CSA recognized, detachable screw terminals

HOBO 4-Channel External

Analog channels: 0 to 2.5 Vdc (w/CABLE-2.5-STEREO); 0 to 5 Vdc (w/CABLE-ADAP5); 0 to 10 Vdc (w/ CABLE-ADAP10); 0 to 24 Vdc (w/CABLE-4-20MA) Accuracy (logger

Veris 480 V, 100 Amp

Includes: 3 100 Amp Split-Core Current Transformers (CT) Input primary voltage: 480 Volts AC rms Accuracy: ±1% per ANSI (C12.1) (from 10 to 100% of CT

Ashcroft (500-psig)

Measurement ranges: 100, 200, 500 psig Compensated temp range: -40° to 125°C (-40° to 257°F) Accuracy: ±1% FS from -20° to

Ashcroft (200-psig)

Measurement ranges: 100, 200, 500 psig Compensated temp range: -40° to 125°C (-40° to 257°F) Accuracy: ±1% FS from -20°

Ashcroft (100-psig)

Measurement ranges: 100, 200, 500 psig Compensated temp range: -40° to 125°C (-40° to 257°F) Accuracy: ±1% FS from -20° to

Dissolved Oxygen Data

Dissolved Oxygen   Sensor Type: Optical Measurement Range: 0 to 30 mg/L Calibrated Range: 0 to 20 mg/L; 0 to 35°C (32 to 95°F) Accuracy:

Differential Air

Media Compatibility Dry air or inert gas Input Power 12-30VDC, or 24VAC nominal Output Field-selectable: 2-wire, loop-powered 4-20mA (DC only, clipped and capped) or 3-wire

Split-Core Bi-Polar DC

Produk ini berasal dari Amerika Serikat. Untuk melihat spesifikasi lengkap produk ini, jika tersedia lihat manual book yang terdapat pada tab dokumentasi. DC Amperage

Salt Water

Measurements: Actual Conductivity, Temperature, Specific Conductance at 25C (calculated), Salinity (calculated using PSS-78, the Practical Salinity Scale 1978) Conductivity

HOBO Fresh Water

Produk ini berasal dari Amerika Serikat. Untuk melihat spesifikasi lengkap produk ini, jika tersedia lihat manual book yang terdapat pada tab dokumentasi. Memory: 18,500

Compressed Air Flow

Measurement range, 5200 model: 1 - 80 SCFM Measurement range, 5400 model: 40-600 SCFM (calibrated), 350 - 600 (uncalibrated) Accuracy: (5200 model) 5% of reading plus 1% of

Compressed Air Flow

Measurement range, 5200 model: 1 - 80 SCFM Measurement range, 5400 model: 16-200 SCFM (calibrated), 350 - 600 (uncalibrated) Accuracy: (5200 model) 5% of reading plus 1% of

C02 and Temp output

Masukkan keterangan produk

Sensor output cable for

Plug directly into the external input jacks of U12 Family loggers to expand the range of measurement options and

Telaire 7001 CO2 Sensor

Measurement Range  When using the CABLE-CO2 and a U12 or ZW: 0 to 2500 ppm When using the CABLE-2070 and a H22 or U30: 0 to 4000 ppm  Telaire 7001

Smart Barometric

Measurement range: 660 to 1070 mbar (19.47 to 31.55 in. Hg) Accuracy: ±3.0 mbar (0.088 in. Hg) over full pressure range at 25°C (77°F); maximum error

HWS Barometric Pressure

Measurement parameters: average over logging interval, user-defined sampling interval from 1 second Measurement range: 660 mb to 1070 mb (19.47 to 31.55 in. Hg) Operating

Air Velocity (.15 to 5

Measurement range (O) model: 0.15 - 5 m/s (30 - 985 fpm) Measurement range (P) model: 0.15 - 10 m/s (30 - 1969 fpm) Accuracy: Greater of 10 % of reading or +/-0.05 m/s or 1 %

Air Velocity (0.15 to 5

Measurement range (O) model: 0.15 - 5 m/s (30 - 985 fpm) Measurement range (P) model: 0.15 - 10 m/s (30 - 1969 fpm) Accuracy: Greater of 10% of reading or +/-0.05 m/s or 1 %

Air Velocity Sensor

Measurement range "O" model: 0.15 - 5 m/s (30 - 985 fpm) Measurement range "P" model: 0.15 - 10 m/s (30 - 1969 fpm) Accuracy: Greater of 10% of reading or

Air Velocity (0.15 to 10

Measurement range "O" model: 0.15 - 5 m/s (30 - 985 fpm Measurement range "P" model: 0.15 - 10 m/s (30 - 1969 fpm) Accuracy: Greater of 10% of reading or

ConLab 0-300 Volt AC

Ranges: 0–300 volts RMS Sensor accuracy: < ±0.1% of span (20% to 120% of range) ±0.25% of span (10% of range) Over range: +20% of

ConLab 0-150 Volt AC

Ranges: 0–150 volts RMS Sensor accuracy: < ±0.1% of span (20% to 120% of range) ±0.25% of span (10% of range) Overrange: +20% of

600 Volt AC Potential

Measurement range: 150, 300, 600 Volts AC Accuracy: ±1% (from 10% to 130% of rated voltage) Phase angle: Output signal to FlexSmart Module: 0.333 Volt at rated

300 Volt AC Potential

Measurement range: 150, 300, 600 Volts AC Accuracy: ±1% (from 10% to 130% of rated voltage) Phase angle: Output signal to FlexSmart Module: 0.333 Volt at rated

150 Volt AC Potential

Measurement range: 150, 300, 600 Volts AC Accuracy: ±1% (from 10% to 130% of rated voltage) Phase angle: Output signal to FlexSmart Module: 0.333 Volt at rated

0 to 24 VoltsDC Voltage

Max. input: 0–24 VDC Accuracy with U12: ±20 mV ±2.7% of reading Accuracy with ZW: N/A Accuracy with UX120-006M: ±1.0 mV

0 to 10 VoltsDC Voltage

Max. input: 0–10 VDC Accuracy with U12:±8 mV ±2.7% of reading Accuracy with ZW: ±6.2 mV ±2.2% Accuracy with UX120-006M:

0 to 5 VoltsDC Voltage

Max. input: 0–5 VDC Accuracy with U12: ±4 mV ±2.7% of reading Accuracy with ZW: ±3.1 mV ±2.2% Accuracy with UX120-006M:

250 Amp Accu-CT

Akurasi: ± 0,75% dari 1% hingga 120% dari rate arus utama Fase sudut: ± 0,5 derajat (30 menit) dari 1% hingga 120% dari arus pengenal Standar Akurasi:

100 Amp Accu-CT

Accuracy: ±0.75% from 1% to 120% of rated primary current Phase angle: ±0.5 degrees (30 minutes) from 1% to 120% of rated current Accuracy standards:

50 Amp Accu-CT

Accuracy: ±0.75% from 1% to 120% of rated primary current Phase angle: ±0.5 degrees (30 minutes) from 1% to 120% of rated current Accuracy standards:

20 Amp Accu-CT

Accuracy: ±0.75% from 1% to 120% of rated primary current Phase angle: ±0.5 degrees (30 minutes) from 1% to 120% of rated current Accuracy standards:

600 AMP Split-core AC

Rated input from 60 Amp to 600 Amp Output 0.333 Volt AC at rated current Operates from 30 Hz to 1,000 Hz Phase angle < 2 degrees measured at 50% rated

200 AMP Split-core AC

Rated input from 20 Amp to 200 Amp Output 0.333 Volt AC at rated current Operates from 30 Hz to 1,000 Hz Phase angle < 2 degrees measured at 50% rated

100 AMP Split-core AC

Rated input from 0 Amp to 100 Amp Output 0.333 Volt AC at rated current Operates from 30 Hz to 1,000 Hz Phase angle < 2 degrees measured at 50% rated

60 - 600 Amp split-core

Range: 60-600 Amps   Accuracy with H8: ±5.0% of full scale Accuracy with U12: ±4.5% of full scale Accuracy with UX120-006M:

20-200 Amp split-core AC

Range: 20-200 Amps   Accuracy with H8: ±5.0% of full scale Accuracy with U12: ±4.5% of full scale Accuracy with UX120-006M:

10-100 Amp split-core AC

Range: 10-100 Amps   Accuracy with H8: ±5.0% of full scale Accuracy with U12: ±4.5% of full scale Accuracy with UX120-006M:

5-50 Amp split-core AC

Range: 5-50 Amps   Accuracy with H8: ±5.0% of full scale Accuracy with U12: ±4.5% of full scale Accuracy with UX120-006M:

2-20 Amp split-core AC

Range: 2-20 Amps   Accuracy with H8: ±5.0% of full scale Accuracy with U12: ±4.5% of full scale Accuracy with UX120-006M:

75 AMP Mini Split-core

Rated input from 7.5 to 75 AMP Output 0.333 Volt AC at rated current Operates from 50 Hz to 400 Hz UL Recognized, CE and RoHS compliant Linearity accuracy ± 1% 8

50 AMP Mini Split-core

Rated input from 5 to 50 AMP Output 0.333 Volt AC at rated current Operates from 50 Hz to 400 Hz UL Recognized, CE and RoHS compliant Linearity accuracy ± 1% 8

5 AMP Mini Split-core AC

Rated input from 0.5 to 5 AMP Output 0.333 Volt AC at rated current Operates from 50 Hz to 400 Hz UL Recognized, CE and RoHS compliant Linearity accuracy ± 1% 8

20 AMP Mini Split-core

Rated input from 2 to 20 AMP Output 0.333 Volt AC at rated current Operates from 50 Hz to 400 Hz UL Recognized, CE and RoHS compliant Linearity accuracy ± 1% 8

4 to 20 mA Input -

Measurement range: 0 to 20.1 mA Accuracy with U12: ±0.02 mA ±2.5% of absolute current Accuracy with ZW: ±0.015 mA ±2.0% of absolute

12-bit 4-20mA Input

  Measurement range: 4-20 mA (measures down to 0 mA to detect error condition) Operating temperature range: -40° to 75°C (-40° to

Showing 1 to 15 of 15 (1 Pages)