| SPECIFICATIONS |
|
| INPUT SIGNAL |
4-20mA(Span/Zero fine adjuster provided) |
| INDICATION RANGE |
Can be set at 0 to intended value on scale value. |
| INDICATOR |
7-segment red LED,5-degit. |
| SAMPPLING CYCLE |
Can be set at 0.1/0.2/0.5/1/2/5 seconds. |
| ACCURACY |
±0.3%±1digits(23°C±5°C) |
| POWER SUPPLY FOR CONVERTER |
+24V DC,50mA max. |
| ALARM SETTING |
2 hight limit positions AL Ⅰ(HH) and AL Ⅱ(H) |
| ALARM VALUE CHECK |
Indicated by pressing AL I or II |
| ALARM RELAY CONTACT |
Transfer.Rating AC 250V 5A, DC30V 5A max. |
| ALARM DELAY |
Can be set at 0-99.99 sec. as desired. |
| ANALOG OUTPUT(OPTION) |
4-20mA(500Ωmax),0-5V,1-5V,0-10V(2KΩmin) when ordering. |
| POWER SUPPLY |
AC85-264V 50/60Hz, 15VA max. |
| OPERATING TEMP.AND HUMIDITY |
0-50°C,45-85%RH max.(No dewing shall occur.) |
| DIMENSIONS AND WEIGHT |
96(W)×48(H)×90.4(D)mm Approx 300g |