SPECIFICATIONS
|
| Measuring contents |
1590-01 |
Seismic vibration displacement |
|
1590-03 |
Indicating the larger displacement of the two radial displacements of a rotor. |
| Frequency range |
1590-01 |
5Hz-50Hx ±5% |
|
1590-03 |
2Hz-100Hz ±5% |
| Measuring range |
0-600μmp-p/FS |
| Indicator scale |
Same as the above. Minimum scale is 1/30 of FS and GAP 0-4mmp-p. |
| Signal input |
Terminal on the rear panel. |
|
Input sensitivity conforms to TQ402/IQS452 |
| Monitor output |
10Vp-p/FS, Load: 500Ωmax. |
|
1590-01: Displacement wave signal, Terminal of the front panel. |
|
1590-03: Displacement wave signal of X,Y direction. |
|
BNC connector of the front panel. |
| OK Monitor lamp |
Lamp indication in normal ready condition. |
| Relay contact output |
SPDT(both ALERT and DENGER output) |
|
Capacity AC: 220Vmax, 4Amax, 400VAmax. |
|
DC: 110Vmax, 3Amax,50Wmax. |
| Alarm delay action |
Auto resetting action, Delay 60sec. |
| Recorder output |
DC 4-20mA, Load: 500Ωmax. |
| Signal input |
Terminal on the rear panel. |
| Power requirement |
AC220V ±10% 50/60Hz 20VA max. |
| Temperature |
Operating: 0-50°C, Storage: -20-+70°C |